INSTALLATION & OPERATING
INSTRUCTIONS
360º FLUSH MOUNT
CEILING PIR LIGHT
CONTROLLER
Cat No. SLFM360
SLFM360_Instruct_art_2.2.qxd 3/5/06 10:05 am Page 12
Przeglądanie stron 0
1 2 3 4 5 6 ... 11 12

Podsumowanie treści

Strona 1 - INSTRUCTIONS

INSTALLATION & OPERATINGINSTRUCTIONS360º FLUSH MOUNTCEILING PIR LIGHTCONTROLLERCat No. SLFM360SLFM360_Instruct_art_2.2.qxd 3/5/06 10:05 am Page

Strona 2 - Introduction

9 1SolutionCover PIR lens with a thick cloth. If thelight turns out, check detection area forheat or reflective source.If the light stays on, check wi

Strona 3 - Factory fitted

10Up to 6 metres diameter (3m Radius) at mountingheight of 2.5m360º230 V AC ~ 50Hz2000W (e.g.20 x 100W GLS)Incandescent/filament or500W Fluorescent/lo

Strona 4 - Tools and parts needed

HELPLINE020-8450-0515For a product brochure please contact:Timeguard Ltd.Victory Park, 400 Edgware Road,London NW2 6ND020-8452-1112or email csc@timegu

Strona 5 - Installation

1IntroductionThe SLFM360 utilises passive infrared technology todetect heat radiation of moving human bodies.Upondetection, the attached lighting load

Strona 6 - Connection

2Wiring coverFactory fittedbridge wireREMOVEDL1LNESwitchedLoadOUTFactory fittedbridge wireLevering areaTime On settingLux -Dusk/DawnsettingMains Suppl

Strona 7 - Setting up

3Parts included• PIR Sensor unit.• Instruction manual. Please keep safe for future reference.• Accessory Pack. Includes wiring cover, 2 x cable clamps

Strona 8

4optimum height of 2.5m.Careful positioning of the sensor will be required toensure optimum performance. See diagram A detailingdetection range and di

Strona 9

5ConnectionTHERE ARE 2 POSSIBLE CONNECTION SCENARIOS1. Standard connection (see diagram E).The factory fitted “bridge” wire must not be removed.Connec

Strona 10 - Troubleshooting guide

6Setting upWalk Test ProcedureTIME - Fully anti-clockwise DUSK - Fully clockwiseThe unit will now operate during daytime as well as atnight, illuminat

Strona 11 - Technical specifications

7Setting Up for Automatic OperationWhen walk tests are complete, the unit can be adjustedfor automatic operation :To access the controls use a knife o

Strona 12 - 020-8450-0515

8to operate too early (ie. when it is quite light), adjustthe control slightly anti-clockwise. If the unit starts tooperate too late (ie. dusk), adjus

Komentarze do niniejszej Instrukcji