INSTALLATION & OPERATING
INSTRUCTIONS
500W MULTI PIR
HALOGEN FLOODLIGHT
Cat No. MLB500C - Black
Cat No. MLW500C - White
150W MULTI PIR
HALOGEN FLOODLIGHT
Cat No. MLB150C - Black
Cat No. MLW150C - White
Installation & Operating
Instructions
Przeglądanie stron 0
1 2 3 4 5 6 ... 11 12

Podsumowanie treści

Strona 1 - 150W MULTI PIR

INSTALLATION & OPERATING INSTRUCTIONS500W MULTI PIR HALOGEN FLOODLIGHTCat No. MLB500C - BlackCat No. MLW500C - White 150W MULTI PIR HALOGEN FLO

Strona 2 - SECTION TWO

SECTION SIXTROUBLESHOOTING GUIDEPROBLEMo Lamp staysON all the time at night.o PIR keeps activating for no reason / at random.SOLUTIONThe unit may

Strona 3 - INSTALLATION

PROBLEMo PIR sensor will not operate at all.o The PIR sensor will not operate at night.o Unit activates during the daytimeo PIR coverage is poor/sp

Strona 4

HELPLINE 020-8450-0515or email [email protected] a product brochure please contact:Timeguard Ltd.Victory Park, 400 Edgware Road, London NW2 6N

Strona 5

SECTION ONEGENERAL INFORMATIONThe unit utilises passive infrared technology to detect heat radiation of moving human bodies. Upon detection, the lamp

Strona 6 - OPERATION AND TESTING

SECTION THREEINSTALLATIONAfter choosing a suitable location (see previous section) install the unit as follows:Remove the wiring box cover by unscrewi

Strona 7

Place this edge against walland use diagram to estimate incoming cable length75mm (3”)25mm (1”)INCOMING WIRE TEMPLATEUse this diagram to estimate inco

Strona 8 - TECHNICAL SPECIFICATIONS

EGFHLens MaskRestrict long detection Restrict short detectionRestrict RHS detection Restrict LHS detectionDusk/DawnHoliday ModeTime

Strona 9

CONNECTION DIAGRAMMains SupplyIsolation SwitchSECTION FOUROPERATION AND TESTINGWALK TEST PROCEDUREThe sensor will rotate from left to right, and tilt

Strona 10 - 020 8450 0515

LesssensitiveMoresensitiveTOP VIEW200ºSIDE VIEW12m2.5mA CBD

Strona 11 - GUARANTEE

Manual Override Mode is indicated by the permanent illumination of a single red LED in the top of the sensor head. To switch the unit back into Auto M

Strona 12 - 020-8450-0515

TEST MODE - THREE LEDS VISIBLEThe lamp will now illuminate for approximately 2 seconds every time movement is detected.Walk across the detection area